Control Room: Difference between revisions

From Unofficial Homecoming Wiki
Jump to navigation Jump to search
imported>Ephemerus
imported>Thirty7
mNo edit summary
 
(16 intermediate revisions by 5 users not shown)
Line 1: Line 1:
__toc__
== Overview ==
 
All information on this page is current as of [[Issue 13]].
 
A '''Control Room''' is <u>required</u> for the placement of any [[Bases|Base's]] main Control-producing [[Base Items]] as well as any Control Auxiliary Base Items that require a connection to a main Control-producing Base Item. Control is required to operate many Base Items such as Defensive, Transportation, and Workshop types.
 
The [[Death Trap]] defense room can also act as a control room.


== Overview ==
The [[Oversight Center]] is a control room that also acts as an [[Energy Room]].


A '''Control Room''' is required for the placement of any [[Bases|Base's]] main Control-producing [[Base Items]] as well as any Control Auxillary [[Base Items]] that require a Connection to a main Control-producing [[Base Items|Base Item]]. Control-producing [[Base Items]] are required to operate many [[Base Items]] such as Defensive, Transportation, and Workshop types. Such [[Base Items]] will not operate without a functional '''Control Room''' <u>and</u> [[Energy Room]]
All control rooms allow 1 storage item and 1 anchor as well as unlimited decorative items. Rooms that allow defensive items allow unlimited defensive auxiliary items.


All control rooms allow 1 storage item and 1 anchor as well as unlimited decorative items. Rooms that allow defensive items allow unlimited defensive auxillary items.
Since control items have a max of 9 aux connections it is unclear why it would be necessary for a control room to support more than 18 aux items. Also, bases are limited to a maximum of 6 batteries which is something to keep in mind when considering how many batteries a control room can hold.


== Types ==
== Types ==


''Note: Numbers after Titles are for paragonwiki designation. Base Editor has '''no''' numeric Titles.''
<small>''Note: Numbers after Titles are for paragonwiki designation. Base Editor has '''no''' numeric Titles.''</small>


{| class="wikitable sortable" width="80%" border=1
|-
! '''Name''' !! '''Price''' !! '''Dimensions''' !! '''Control''' !! '''Control Aux''' !! '''Batteries''' !! '''Defense'''
|-


{| border="0" cellpadding="3" cellspacing="0"
| nowrap | [[Oversight Center]] || align="right" nowrap | 50,000 [[prestige]]
|-----
| '''Title''' || align="right" | '''Price'''
| '''Dimensions''' || '''Description'''
|-----
| nowrap | [[Oversight Center]] || align="right" nowrap | 50 000
| align="center" | 3x3
| align="center" | 3x3
| valign="top" | This room is used for establishing a small base quickly, and can house the most basic needs of a base.
| Only [[Combo Power and Control Unit|Combo Unit]]
|-----
| 0
| 0
| 0
|-
| nowrap | [[Control Room 1]]
| nowrap | [[Control Room 1]]
| align="right" valign="top" nowrap | 100 000
| align="right" valign="top" nowrap | 100,000 [[prestige]]
| align="center" | 2x2
| align="center" | 2x2
| valign="top" | This room can hold a few pieces of Control equipment.
| 1
|----- bgcolor="cccccc"
| 4
| 0
| 0
|-
| valign="top" nowrap | [[Control Room 2]]
| valign="top" nowrap | [[Control Room 2]]
| align="right" valign="top" nowrap | 150 000
| align="right" valign="top" nowrap | 130,000 [[prestige]]
| align="center" | 1x4
| align="center" | 1x4
| This room can hold a few pieces of Control equipment.
| 1
|-----
| 6
| nowrap | [[Control Room 3]] || align="right" nowrap | 750 000
| 0
| 0
|-
| nowrap | [[Control Room 3]]  
| align="right" nowrap | 145,000 [[prestige]]
| align="center" | 2x3
| align="center" | 2x3
| This room can hold a few pieces of Control equipment
| 1
|----- bgcolor="cccccc"
| 6
| nowrap | [[Control Room 4]] || align="right" nowrap | 1 500 000
| 0
| 0
|-
| nowrap | [[Control Room 4]]
| align="right" nowrap | 162,000 [[prestige]]
| align="center" | 3x3
| align="center" | 3x3
| This room can hold a moderate amount of Control equipment.
| 1
|-----
| 15
| nowrap | [[Secure Control Room]] || align="right" nowrap | 1 750 000
| 1
| 0
|-
| nowrap | [[Secure Control Room]]
| align="right" nowrap | 159,000 [[prestige]]
| align="center" | 2x3
| align="center" | 2x3
| This room can hold a moderate amount of Control equipment. Some defensive items can be placed as well.
| 1
|----- bgcolor="cccccc"
| 10
| nowrap | [[Communication Center 1]] || align="right" nowrap | 2 500 000
| 1
| 1
|-
| nowrap | [[Communication Center 1]]  
| align="right" nowrap | 253,000 [[prestige]]
| align="center" | 3x4
| align="center" | 3x4
| This room can hold a moderate amount of Control equipment. Some defensive items can be placed as well.
| 1
|-----
| 15
| nowrap | [[Communication Center 2]] || align="right" nowrap | 3 950 000
| 1
| 1
|-
| nowrap | [[Communication Center 2]]
| align="right" nowrap | 275,000 [[prestige]]
| align="center" | 4x4
| align="center" | 4x4
| This room can hold a large amount of Control equipment. Some defensive items can be placed as well.
| 1
|----- bgcolor="cccccc"
| 18
| nowrap | [[Operations Center]] || align="right" nowrap | 5 000 000
| 1
| 2
|-
| nowrap | [[Operations Center]]
| align="right" nowrap | 398,750 [[prestige]]
| align="center" | 5x5
| align="center" | 5x5
| This room can hold a huge amount of Control equipment. Some defensive items can be placed as well.
| 2
|-----
| 25
| nowrap | [[Secure Comm Center 1]] || align="right" nowrap | 5 950 000
| 1
| 2
|-
| nowrap | [[Secure Comm Center 1]]
| align="right" nowrap | 401,500 [[prestige]]
| align="center" | 3x6
| align="center" | 3x6
| This room can hold a large amount of Control equipment. Moderate defensive items can be placed as well.
| 2
|----- bgcolor="cccccc"
| 18
| nowrap | [[Secure Comm Center 2]] || align="right" nowrap | 6 250 000
| 2
| 4
|-
| nowrap | [[Secure Comm Center 2]]
| align="right" nowrap | 374,000 [[prestige]]
| align="center" | 4x5
| align="center" | 4x5
| This room can hold a large amount of Control equipment. Moderate defensive items and backup energy can be placed as well.
| 2
|-----
| 20
| nowrap | [[Secure Ops Center]] || align="right" nowrap | 8 450 000
| 3
| 4
|-
| nowrap | [[Secure Ops Center]]
| align="right" nowrap | 572,000 [[prestige]]
| align="center" | 4x7
| align="center" | 4x7
| This room can hold a huge amount of Control equipment. Moderate defensive items and backup energy can be placed as well.
| 2
|----- bgcolor="cccccc"
| 28
| nowrap | [[Command Center]] || align="right" nowrap | 12 500 000
| 4
| 5
|-
| nowrap | [[Command Center]]
| align="right" nowrap | 646,250 [[prestige]]
| align="center" | 5x7
| align="center" | 5x7
| This room can hold an enourmous amount of Control equipment. Substantial defensive items and backup energy can be placed as well.
| 2
|}
| 35
 
| 6
 
| 8
 
{| border="0" cellpadding="3" cellspacing="0"
|-----
| '''Title''' || align="right" | '''Control'''
| '''Control Aux''' || '''Batteries''' || '''Defense'''
|-----
| nowrap | [[Control Room 1]]
| align="center" | 1
| align="center" | 4
| align="center" | 0
| align="center" | 0
|----- bgcolor="cccccc"
| valign="top" nowrap | [[Control Room 2]]
| align="center" | 1
| align="center" | 6
| align="center" | 0
| align="center" | 0
|-----
| nowrap | [[Control Room 3]]
| align="center" | 1
| align="center" | 10
| align="center" | 1
| align="center" | 0
|----- bgcolor="cccccc"
| nowrap | [[Control Room 4]]
| align="center" | 1
| align="center" | 15
| align="center" | 1
| align="center" | 0
|-----
| nowrap | [[Secure Control Room]]
| align="center" | 1
| align="center" | 10
| align="center" | 1
| align="center" | 1
|----- bgcolor="cccccc"
| nowrap | [[Communication Center 1]]
| align="center" | 1
| align="center" | 15
| align="center" | 1
| align="center" | 1
|-----
| nowrap | [[Communication Center 2]]
| align="center" | 1
| align="center" | 18
| align="center" | 1
| align="center" | 2
|----- bgcolor="cccccc"
| nowrap | [[Operations Center]]
| align="center" | 2
| align="center" | 25
| align="center" | 1
| align="center" | 2
|-----
| nowrap | [[Secure Comm Center 1]]
| align="center" | 2
| align="center" | 18
| align="center" | 2
| align="center" | 4
|----- bgcolor="cccccc"
| nowrap | [[Secure Comm Center 2]]
| align="center" | 2
| align="center" | 20
| align="center" | 3
| align="center" | 4
|-----
| nowrap | [[Secure Ops Center]]
| align="center" | 2
| align="center" | 28
| align="center" | 4
| align="center" | 5
|----- bgcolor="cccccc"
| nowrap | [[Command Center]]
| align="center" | 2
| align="center" | 35
| align="center" | Unlim
| align="center" | 8
|}
|}


== Related Subjects ==
{{Navbox SG Bases}}
 
[[Base Items]]
 
[[Base Plots]]
 
[[Base Upgrades]]


[[Category:Base Rooms| Control Room]]
[[Category:Base Rooms| Control Room]]

Latest revision as of 09:00, 8 July 2012

Overview

All information on this page is current as of Issue 13.

A Control Room is required for the placement of any Base's main Control-producing Base Items as well as any Control Auxiliary Base Items that require a connection to a main Control-producing Base Item. Control is required to operate many Base Items such as Defensive, Transportation, and Workshop types.

The Death Trap defense room can also act as a control room.

The Oversight Center is a control room that also acts as an Energy Room.

All control rooms allow 1 storage item and 1 anchor as well as unlimited decorative items. Rooms that allow defensive items allow unlimited defensive auxiliary items.

Since control items have a max of 9 aux connections it is unclear why it would be necessary for a control room to support more than 18 aux items. Also, bases are limited to a maximum of 6 batteries which is something to keep in mind when considering how many batteries a control room can hold.

Types

Note: Numbers after Titles are for paragonwiki designation. Base Editor has no numeric Titles.

Name Price Dimensions Control Control Aux Batteries Defense
Oversight Center 50,000 prestige 3x3 Only Combo Unit 0 0 0
Control Room 1 100,000 prestige 2x2 1 4 0 0
Control Room 2 130,000 prestige 1x4 1 6 0 0
Control Room 3 145,000 prestige 2x3 1 6 0 0
Control Room 4 162,000 prestige 3x3 1 15 1 0
Secure Control Room 159,000 prestige 2x3 1 10 1 1
Communication Center 1 253,000 prestige 3x4 1 15 1 1
Communication Center 2 275,000 prestige 4x4 1 18 1 2
Operations Center 398,750 prestige 5x5 2 25 1 2
Secure Comm Center 1 401,500 prestige 3x6 2 18 2 4
Secure Comm Center 2 374,000 prestige 4x5 2 20 3 4
Secure Ops Center 572,000 prestige 4x7 2 28 4 5
Command Center 646,250 prestige 5x7 2 35 6 8